As a supplier of 19" Power Distribution Units (PDUs), I often get asked about the different mounting options available for these essential pieces of equipment. In this blog post, I'll delve into the various ways you can mount a 19" PDU and help you understand which option might be best for your specific needs.
Rack - Mounting
Rack - mounting is by far the most common way to install a 19" PDU. It's designed specifically for use within server racks, data centers, and other network equipment enclosures.
Front - Mounted
Front - mounted 19" PDUs are installed on the front of the rack. This placement makes it easy to access the outlets, which is great for quick plug - ins and unplugging of devices. It's also convenient for visual inspection. When you're walking in front of the rack, you can easily see if all the connected devices are properly plugged in and receiving power.
For example, if you're managing a small server room and need to regularly connect and disconnect testing equipment, a front - mounted PDU is a practical choice. We offer several models like the 19" US American Type PDU Socket Rack Mounted with Switch, which can be front - mounted in a standard 19 - inch rack. This PDU comes with a switch, allowing you to control the power distribution easily.
Rear - Mounted
Rear - mounted PDUs are installed at the back of the rack. They're ideal for situations where you want to keep the front of the rack clean and organized, especially when dealing with a high - density rack setup. By placing the PDU at the rear, you can route the power cables neatly to the back of the servers and other equipment.
This setup also helps in reducing cable clutter at the front, which can improve airflow within the rack. Our 19 Germany French EU Series PDU Socket Rack Mounted with Switch is a great option for rear - mounting. It's built to meet the power requirements of European - style equipment and can be easily integrated into a rear - mounted configuration.
Wall - Mounting
Wall - mounting a 19" PDU is a good option when you don't have a rack or when you want to install the PDU in a location outside of a traditional rack environment.
Indoor Wall - Mounting
For indoor use, such as in a small office or a home server setup, wall - mounting can save space and keep the PDU out of the way. You can mount the PDU at a convenient height for easy access. This is especially useful if you have limited floor or rack space.
Our 19 UK British Series PDU Socket Rack Mounted with Switch can also be wall - mounted. It's designed to handle the power requirements of British standard equipment and provides a reliable power source when installed on an indoor wall.
Outdoor Wall - Mounting
In some cases, you may need to mount a PDU outdoors, such as in a telecommunications cabinet or a small outdoor server enclosure. When choosing an outdoor wall - mount option, you need to ensure that the PDU is weatherproof and can withstand the elements.
We offer specialized outdoor - rated 19" PDUs that are built to be durable and resistant to factors like rain, dust, and extreme temperatures. These PDUs can be safely mounted on an outdoor wall to power equipment in harsh environments.
Floor - Mounting
Floor - mounting is another option, especially in large data centers or industrial settings.
Raised Floor Mounting
In a raised - floor data center, the PDU can be mounted underneath the raised floor. This helps in keeping the power distribution system hidden and out of the way, reducing the tripping hazard. It also allows for better cable management, as the power cables can be routed through the floor channels.


The advantage of raised floor mounting is that it provides a clean and organized look to the data center. It's also easier to access the PDU for maintenance and upgrades when needed.
On - Site Floor Mounting
In some industrial environments, the PDU can be mounted directly on the floor. This is suitable for heavy - duty equipment that requires a stable and direct power source. The PDU can be securely fastened to the floor to prevent any movement or damage.
Choosing the Right Mounting Option
When choosing the mounting option for your 19" PDU, you need to consider several factors.
Space Constraints
If you have limited rack space, a front - or rear - mounted PDU may be your best bet. On the other hand, if you have plenty of wall space but no racks, wall - mounting is a practical choice. And in large open spaces, floor - mounting might be more suitable.
Accessibility
Think about how often you'll need to access the PDU. If you need to plug and unplug devices frequently, a front - mounted or wall - mounted PDU will be more accessible. If you only need to access it for maintenance, a rear - mounted or floor - mounted option may be sufficient.
Environmental Conditions
For outdoor or harsh indoor environments, make sure the chosen mounting option and the PDU itself are suitable for the conditions. For example, outdoor - rated PDUs are necessary for outdoor wall - mounting.
As a trusted 19" PDU supplier, we understand that every situation is unique. That's why we offer a wide range of PDUs with different mounting options to meet your specific needs. Whether you need a PDU for a small office setup or a large - scale data center, we've got you covered.
If you're interested in purchasing a 19" PDU or need more information about our products, feel free to reach out to us. We'd be more than happy to assist you in finding the right PDU and mounting option for your requirements. You can also check out the following products on our website: 19 Australia Type PDU Socket Rack Mounted with Switch, 19 Germany French EU Series PDU Socket Rack Mounted with Switch, 19'' US American Type PDU Socket Rack Mounted with Switch, and 19 UK British Series PDU Socket Rack Mounted with Switch.