What are the storage requirements for a Common PDU?

Jan 01, 2026

Leave a message

What are the storage requirements for a Common PDU?

As a supplier of Common Power Distribution Units (PDUs), I understand the importance of proper storage to maintain the quality and functionality of these essential electrical devices. PDUs are used in various applications, from data centers to industrial settings, to distribute electrical power safely and efficiently. In this blog post, I'll delve into the key storage requirements for a Common PDU to ensure its longevity and reliable performance.

Temperature and Humidity Control

One of the most critical factors in PDU storage is the control of temperature and humidity. Extreme temperatures and high humidity levels can have a detrimental effect on the electrical components of a PDU. For example, high temperatures can cause the insulation materials to degrade over time, increasing the risk of electrical shorts and failures. On the other hand, low temperatures can make the plastic and metal parts more brittle, leading to cracks and damage during handling.

It is recommended to store PDUs in an environment with a temperature range of 0°C to 40°C (32°F to 104°F). This range helps to maintain the integrity of the electrical components and prevents any thermal stress that could lead to premature failure. Additionally, the relative humidity should be kept between 20% and 80% non - condensing. High humidity can cause corrosion on the metal contacts and circuitry of the PDU, which can disrupt the electrical connection and reduce the overall performance.

To ensure proper temperature and humidity control, a climate - controlled storage facility is ideal. This could be a dedicated warehouse with air - conditioning and dehumidification systems. If a climate - controlled environment is not available, it is important to at least store the PDUs in a well - ventilated area away from direct sunlight and sources of heat or moisture.

Protection from Physical Damage

PDUs are relatively robust devices, but they are still susceptible to physical damage during storage. Impact, vibration, and improper handling can all lead to internal damage to the PDU's components. When storing PDUs, it is essential to keep them in their original packaging or in a suitable storage container that provides adequate protection.

The original packaging is designed to absorb shocks and vibrations during transportation and storage. If the original packaging is not available, a sturdy cardboard box or a plastic storage bin can be used. It is important to place the PDUs in an upright position and ensure that they are not stacked in a way that could cause excessive pressure on the bottom units.

Moreover, storing the PDUs away from areas where they could be knocked over or stepped on is crucial. This might mean designating a specific storage rack or shelf for the PDUs and keeping them out of high - traffic areas.

Dust and Dirt Prevention

Dust and dirt can accumulate on the PDU's surface and inside its components over time. This can cause a variety of problems, such as reduced airflow, increased electrical resistance, and potential short circuits. To prevent dust and dirt from accumulating on the PDUs, they should be stored in a clean environment.

If possible, the storage area should be regularly cleaned to remove any dust or debris. The PDUs can also be covered with a dust - proof cover or plastic sheet when not in use. Additionally, it is important to avoid storing the PDUs near areas where there is a lot of construction or other activities that generate dust.

Electrical Isolation

During storage, it is important to ensure that the PDUs are electrically isolated. This means disconnecting them from any power sources and ensuring that there are no live electrical connections. Electrical isolation helps to prevent any accidental electrical shocks or damage to the PDU's components.

Before storing the PDUs, make sure to turn off the power switch and unplug them from the electrical outlet. If the PDUs have any removable fuses or circuit breakers, they should be removed and stored separately. This not only provides an extra layer of electrical safety but also helps to protect the fuses and circuit breakers from damage during storage.

Storage of Accessories

PDUs often come with various accessories, such as power cords, mounting brackets, and user manuals. These accessories should be stored together with the PDU to ensure that they are available when the PDU is installed.

The power cords should be neatly coiled and stored in a way that prevents them from getting tangled or damaged. The mounting brackets should be kept in a separate container or attached to the PDU in a secure manner. The user manuals should be stored in a dry place to prevent them from getting wet or damaged.

Our Product Range

At our company, we offer a wide range of Common PDUs to meet the diverse needs of our customers. For example, we have the 19'' US American Type PDU Socket Rack Mounted with Switch, which is designed to provide reliable power distribution in North American data centers and other applications. This PDU features a rack - mountable design and a built - in switch for easy control.

We also offer the 19 Germany French EU Series PDU Socket Rack Mounted with Switch, which is suitable for European markets. This PDU is designed to meet the specific electrical standards and requirements in Germany, France, and other EU countries.

Another popular product is the 19 UK British Series PDU Socket Rack Mounted with Switch, which is designed for use in the UK and other countries that follow British electrical standards. This PDU comes with a rack - mountable design and a switch for convenient power management.

Contact for Purchase and Negotiation

If you are interested in purchasing our Common PDUs or have any questions about their storage or usage, we would be more than happy to assist you. Our team of experts can provide you with detailed product information, technical support, and competitive pricing. Please feel free to reach out to us to start the negotiation process and ensure that you get the best PDU solution for your needs.